Élégant et sophistiqué, avec un profond sens de la texture.
Résistance à l'usure de niveau T, classement anti-dérapant R10 (R11, R12)
Matériau écologique, puissantes propriétés antibactériennes
Scénarios d'application : Restaurants, soins de santé (soins des personnes âgées), gares, toilettes, etc.
Testing Items | Testing method | Test Results |
Appearance | GB/T 11982.2 | Compliant |
Length | GB/T 11982.2 | 20M |
Width | GB/T 11982.2 | 2M |
Overall thickness | GB/T 11982.2 | 2.0mm |
Rate of Dimensional Change After Heating | GB/T 11982.2 | Vertical: 0.09% |
GB/T 11982.2 | Horizontal: 0.10% | |
Thermal Warping | GB/T 11982.2 | 0mm |
Flexibility | GB/T 11982.2 | No cracking |
Chair Caster Test | GB/T 11982.2 | No damage |
Colorfastness | GB/T 11982.2 | > Level 6 |
Residual Depression | GB/T 11982.2 | 0.02mm |
Welding strength | GB/T 11982.2 | Average value: 730 N/50 mm |
GB/T 11982.2 | Minimum value: 713 N/50 mm | |
Wear resistance | GB/T 11982.2 | T-Class |
Coefficient of static friction | GB/T 4100 | Dry method 0.53 |
GB/T 4100 | Wet method 0.53 | |
Non-slip rating | GB/T 11982.2 | R10-R11-R12 |
Pollution resistance | GB/T 11982.2 | Through |
Volatile content | GB 18586 | Compliant |
Soluble lead and cadmium | GB 18586 | Compliant |
Vinyl chloride monomer content | GB 18586 | Not detected |
Combustion performance | GB 8624 | B1 |
Most of the data listed are third-party results obtained solely from sample testing, and variations may occur across different batches or testing institutions.
Inspection Items | Inspection Methods | Test Results |
Length | ISO 24341 | 20m |
Width | ISO 24341 | 2m |
Overall Thickness | ISO 24346 | 2.0mm |
Adhesive Content | ISO 10581 | Class I |
Dimensional Stability | EN ISO 23999 | ≤0.40% |
Color Fastness | EN ISO 105B02 | ≥ Grade 6 |
Chair Caster Test | ISO 4918 | No Damage |
Anti-Slip Performance | EN 16165 | R10-R11-R12 |
Combustion Performance | EN 13501 | B1 |
Stain Resistance | ISO 26987 | Passed |
Seam Strength | EN 684 | ≥400N/50mm |
The listed data mostly represent third-party data based solely on sample testing; differences may exist between batches and testing institutions.